From page 113...
... Establish leakage rates for bottom Accuracy of measurement is a barriers before and after waste function of boundary conditions emplacement and for covers 9. Gas-phase constituent Gas/air samples analyzed using Determine quantity and quality of Complex geospatial modeling may concentrations and flow rates handheld instruments and/or flux gas emissions and air quality be required to analyze downwind through cover systems chambers measurements obtained from tracer tests; point measurements from flux chambers may not capture emission patterns; results of questionable quality 10.
From page 114...
... Vertical barrier leak detection Wells, drainage layers installed Determine the amount of leakage Results of questionable reliability; along the midsection of vertical and thus the performance of vertical rarely used in practice; requires barriers walls installation of the collection and removal system in the barrier; integrity of half of the thickness of the barrier is assessed 20. Radioisotope concentrations Total radiation dose Identify releases and establish Primarily of concern for low-level concentration gradients radioactive waste NOTES: CQA = construction quality assurance; EM = electromagnetic; GPR = ground-penetrating radar; LCRS = leachate collection and removal system; LDS = leak detection system; TDR = time domain reflectometry.


This material may be derived from roughly machine-read images, and so is provided only to facilitate research.
More information on Chapter Skim is available.