From page 9...
... For example, the laboratory standard may call for a Moderate Risk SOP if only a small amount (milliliters) of a highly flammable and moderately toxic solvent will be used but a High Risk SOP if the same solvent will be used at a substantially larger scale.
From page 10...
... Inclusion and exclusion scope criteria Process risk Type of Management and mitigation SOP storage Assessment of Assessment of chemical and process risk type vis Storage conditions Matrix High Risks Moderate Risks Low Risks Storage SOP High Risk SOP Moderate Risk SOP Laboratory standards are sufficient FIGURE 2-1  Risk Assessment Flowchart.
From page 11...
... If the process conditions pose a low level of risk, then the existing laboratory standards1 will be sufficient to minimize concerns about the health and safety of the laboratory personnel and others in the surrounding area. At a minimum, sufficient laboratory standards will address personal apparel and personal protective equipment, laboratory housekeeping, emergency action plan, safety equipment such as eye washes, showers, and fire extinguishers, and handling of chemical waste.