From page 38...
... 38 a p p e N D I x D accuracy The ultrasonic tomography (UST) system used in this study is a device with an array of ultrasonic transducers that transmit and receive acoustic stress waves for the inspection of concrete structures.
From page 39...
... 39 Concrete Slabs with Blind Calibration The two UST systems have been demonstrated to locate 8-in.-deep air- and water-filled voids with a 0.51-in. precision and 2-in.-deep to 3-in.-deep delamination with a 0.55-in.
From page 40...
... 40 Testing Equipment User's Manual. Limitations include the following: • The speed of data acquisition is low (0.8 to 2.3 min/sq ft)