Skip to main content

Currently Skimming:

Appendix B: Single-Event Effects Testing Facilities in the United States
Pages 62-64

The Chapter Skim interface presents what we've algorithmically identified as the most significant single chunk of text within every page in the chapter.
Select key terms on the right to highlight them within pages of the chapter.


From page 62...
... Brookhaven Upton, New <2 MeV Nuclear Vacuum Lower LET Power $1,250 <100 National York for high physics, only work or test devices and $1,500 Laboratory, Z up to 8 radiation structures complex Tandem Van de Mev for effects integrated Graaff, Single- low Z circuits Event Upset Test Facility (SEUTF)
From page 63...
... Medium-Energy Protons Brookhaven Upton, New <29 Nuclear Vacuum Low-energy Ineffective $1,250 <100 National York physics, only proton SEU for revealing Laboratory, radiation studies destructive Tandem Van de effects SEE Graaff, Single- susceptibility Event Upset Test Facility (SEUTF) Crocker Davis, 1–70 Nuclear Air Displacement Ineffective $1,500 700 Nuclear California physics, damage for revealing Laboratory, radiation studies and destructive UC-Davis effects determining SEE (CNL)
From page 64...
... shielding electronics electronics research Loma Linda Loma Linda, 230 Medical Air Suitable for Not effective Data not Data not Cancer California therapy, determining for revealing available available Treatment radiation proton destructive Center effects susceptibilities SEE in most susceptibilities electronics Massachusetts Boston, 230 Medical Air Suitable for Not effective $750 600–800 General Massachusetts therapy, determining for revealing Hospital radiation proton destructive (MGH) effects susceptibilities SEE in most susceptibilities electronics Northwestern Warrenville, 230 Medical Air Suitable for Not effective $1,000 600–800 Medicine Illinois therapy, determining for revealing Chicago Proton radiation proton destructive Center effects susceptibilities SEE in most susceptibilities electronics TRIUMF Vancouver, 70–500 Nuclear Air Suitable for Not effective Data not 500–1,000 Canada physics, determining for revealing available medical proton destructive therapy, susceptibilities SEE radiation in most susceptibilities effects electronics NOTE: This table lists the facilities in the United States (and the TRIUMF facility in Canada)


This material may be derived from roughly machine-read images, and so is provided only to facilitate research.